Fluke ii900 Industrial Acoustic

Fluke ii900 Industrial Acoustic is prepared for usage. Its large7″ LCD display makes it simple to see leaks, and its sturdy and ergonomic design makes it comfortable to carry. Even someone with no prior experience can begin finding leaks in a matter of minutes. The Fluke experts made sure that all the required parts were integrated in and simple to reach while keeping in mind the needs of the ii900 consumers. Furthermore, the Fluke engineers made sure the Fluke ii900 Industrial Acoustic Imager could be utilized in noisy conditions and from a safe distance because they recognized that closing down the plant or placing technicians in danger was not an option.

Fluke ii900 Industrial Acoustic Imager Features

Leak volume and cost indication on the go
CO2 emission reporting
Improve energy efficiency – Do more with the same air compressors and delay the capital expense of purchasing an additional compressor
Lower utility and downtime costs
Reduce time and costs to detect leaks
Improve production process and pneumatic equipment reliability
SoundSight™ technology
Acoustic imaging: Blended live SoundMap™ with visual image
Frequency range from 2 to 52 kHz
Detection range of up to 230′ (70 m)*
7″ (177.8 mm) 1280 x 800 LCD with capacitive touchscreen.

Applications

Hospitals
Power plants
Transportation
Material handling
Oil and gas and mining – refineries, oil rigs, gas processing, and mines
Process manufacturing – F&B, chemical, pharma, glass, cement, pulp and paper
Discrete manufacturing – automotive, heavy machinery, fabricated metal, plastics, and electronics
Fluke ii900 Industrial Acoustic Imager the box:
Fluke ii900 Industrial Acoustic Imager
AC power supply and battery pack charger (including universal AC adapters)
Two rugged lithium ion smart battery packs
USB cable
Rugged, hard carrying case
Adjustable hand strap and neck strap

Specifications: Fluke ii900 Industrial Acoustic Imager

Sensors
# of microphones 64 digital MEMS microphones
Frequency band 2 kHz to 52 kHz
Sound pressure sensitivity Detects a 0.005 CFM leak at 100PSI from up to 32.8 feet
(Detects a 2.5 cm3/sec leak at 7 bar from up to 10 meters)
Operation distance range 0.5 to > 70 meters (1.6 to > 164 feet)*
Field of View 63 ° ± 5 °
Nominal frame rate 25 FPS
*Depending on ambient conditions
Built-in digital camera (visible light)
Field of View (FOV) 63 ° ± 5 °
Focus Fixed lens
Zoom 3 x Digital Zoom
Resolution 1.2 MP
Display 7″ LCD with backlight, under-sunlight readable
Resolution 1280 x 800 (1,024,000 pixels)
Touchscreen Capacitive
Acoustic Image Yes, SoundMap™ image
Image storage
Storage capacity 20GB (>5000 pictures / >999 videos)
Image format Blended visual and SoundMap™.JPG or .PNG
Video format Blended visual and SoundMap™.MP4
Video length Up to 5 minutes
Digital export USB-C for data transfer
Acoustic Measurements
Sound pressure (typical) 15.4 dB to 115.2 dB SPL (±1 dB) at 2 kHz
5.6 dB to 102.5 dB SPL (±2 dB) at 19 kHz
28.4 dB to 131.1 dB SPL (±1 dB) at 35 kHz
41.8 dB to 133.1 dB SPL (±3 dB) at 52 kHz
Auto max/min dB gain Auto or manual, user selectable
Frequency band selection User selectable through user-made presets or manual entry
Classification and quantification LeakQ™
Leak size and cost estimation
Software
Ease of use Intuitive user interface
Trend graphs Frequency and dB scale
Spot markers dB level reading at center point of the image
Asset ID QR code based asset ID identification
Asset Inspection Status: ‘As left’, ‘As found’ ; ‘Undetermined’
Photo notes Up to 4 photos notes for reference
Source Show single or multiple sources
Profile Preset capture profiles
Annotation: Asset name; Asset ID; Asset type; Leak type; Gas type; Pressure;
Other Operating conditions; Weather notes
Leak values Leak costs; Leak volume; LeakQ™ scale
Battery
Batteries (field-replaceable, rechargeable) Rechargeable Li-ion
Battery life 6 hours (product includes spare battery)
Battery charging time 3 hours
Battery charging system External charger
General Specifications
Standard palettes 3: Grayscale, Ironbow, Blue-Red
Operating Temperature -10 °C to 45 °C (14 °F to 113 °F)
Storage Temperature -20 °C to 70 °C (-4 °F to 158 °F) Without batteries
Relative humidity 10 % to 95 % non-condensing
Size (H x W x L) 186 mm x 322 mm x 68 mm (7.3 inches x 12.7 inches x 2.7 inches)
Weight (battery included) 1.8 kg (3.95 pounds)
Ingress Protection (IP) IP40
Warranty 2 year
Fluke Premium Care Premium Care Standard**
Self-diagnostic notification Array-health test to identify when microphone array needs attention
Supported languages Dutch, English, Finish, French, German, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese
RoHS compliant Yes
** Subject to regional availability
Safety
General Safety IEC 61010-1
Electromagnetic Compatibility (EMC) International IEC 61326-1: Portable Electromagnetic Environment IEC 61326-2-2
CISPR 11: Group 1, Class A
Korea (KCC) Class A Equipment (Industrial Broadcasting & Communication)
USA (FCC) 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.

Reviews

There are no reviews yet.

Be the first to review “Fluke ii900 Industrial Acoustic”

Your email address will not be published. Required fields are marked *

Fluke ii900 Industrial Acoustic
You're viewing: Fluke ii900 Industrial Acoustic Original price was: $6,400.00.Current price is: $5,520.00.
Add to cart
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
Click outside to hide the comparison bar